A: ELIWELL NTC 10kΩ at 25°C (probe type: NTC103AT) is standard. PTC probes (PtC) are also supported if you change parameter S1P to “PtC.” Do not use PT100 (RTD) probes; they are incompatible. 10. Conclusion The Eliwell SB655 C is a workhorse of the refrigeration industry. Whether you are building a new cold room or repairing a frozen display case, understanding its manual is key to a long, trouble-free service life. eliwell sb655 c manual
A: The most common default is 3 (three). If that fails, try 5 , 55 , 22 , or 0 . If none work, the password has been changed by a previous technician. You may need to contact technical support for a backdoor reset code. This guide is for informational purposes
| Terminal | Label | Function | Typical Connection | | :--- | :--- | :--- | :--- | | 1 | 12V | +12 Vdc output for probe (power supply) | Connect to probe + | | 2 | GND | Ground reference for probe | Connect to probe - | | 3 | PTC/NTC | Analog input for temperature probe (Probe 1) | Signal wire (typically white or yellow) | | 4 | N | Neutral (Power supply input) | 230V Neutral Line | | 5 | L | Live (Power supply input) | 230V Live Line | | 6 | NO | Normally Open output relay contact | Compressor contactor coil (L1) | | 7 | COM | Common output relay contact | Compressor contactor common | | 8 | NC | Normally Closed (rarely used) | Alarm circuit or unused | PTC probes (PtC) are also supported if you