Eberle Instat 6 User Manual English -

Use Up/Down to select PXX, press Clock, adjust value with Up/Down, press Clock to save. Exit by holding Auto/Manual for 3 seconds. 8. Wiring Diagram and Terminal Assignments Danger: 230V AC present. Only for qualified installers.

To reset all settings to factory defaults (schedule, parameters, time) – Press and hold Clock + Auto/Manual for 10 seconds until all segments flash, then release. 10. Maintenance and Battery Replacement Even though the Instat 6 is mains powered, it contains a lithium coin cell (CR2032) to retain the clock during short power outages. Replace every 2-3 years.

| Parameter | Description | Range | Default | Typical setting | |-----------|-------------|-------|---------|------------------| | P01 | Temperature control type | 0=ON/OFF, 1=PID | 0 | 1 for underfloor heating, 0 for radiators | | P02 | Cycle time (minutes) – only for ON/OFF | 1-30 | 10 | 5 for gas boiler, 15 for electric | | P03 | Minimum setpoint limit | 5-15°C | 5 | 10 (to prevent excessive cooling) | | P04 | Maximum setpoint limit | 20-35°C | 30 | 27 | | P05 | Frost protection temperature | 5-15°C | 7 | 7 | | P06 | Open window detection sensitivity | 0=off, 1-3 (1=low) | 2 | 1 if room has frequent drafts | | P07 | Display brightness | 1-5 | 3 | 2 | | P08 | Sensor calibration offset | -3 to +3°C | 0 | Use if measured temp differs | eberle instat 6 user manual english

| Code | Meaning | Solution | |------|---------|----------| | E1 | Internal sensor fault (open circuit) | Replace thermostat or sensor | | E2 | Internal sensor short circuit | Check for moisture/damage – replace unit | | E5 | External sensor fault (optional) | Check external sensor wiring or disable in P## | | Battery icon flashing | Backup battery low (clock will reset on power loss) | Replace CR2032 battery on PCB (requires opening unit) | | Flame symbol on but room cold | Relay stuck or wiring issue | Check voltage at terminal 2. If 0V, thermostat faulty. If 230V, boiler problem. | | Display blank | No power or internal fuse blown | Check circuit breaker, then test L-N voltage. |

| Terminal | Label | Description | |----------|-------|-------------| | N | Neutral (mains input) | 230V AC neutral | | L | Live (mains input) | 230V AC live | | 1 | Common (COM) | Relay common contact | | 2 | Normally Open (NO) | Relay NO – closes on heat call | | 3 | Normally Closed (NC) | Not used in most heating systems | | (S1, S2) | External sensor | Optional floor sensor (if equipped) | Use Up/Down to select PXX, press Clock, adjust

Last Updated: May 2026 Product Focus: Eberle Instat 6 Electronic Room Thermostat

| Button | Symbol | Function | |--------|--------|----------| | 1 | Up arrow (▲) | Increase temperature / navigate menu up | | 2 | Down arrow (▼) | Decrease temperature / navigate menu down | | 3 | Clock (🕘) | Enter programming / time settings / confirm | | 4 | Auto/Manual (👤) | Switch between Auto (schedule) and Manual (permanent hold) | | 5 | On/Off (⏻) | Power / standby (frost protection remains active) | Wiring Diagram and Terminal Assignments Danger: 230V AC

The Eberle Instat 6 uses screw terminals on the rear. Ensure correct wire gauge (0.5-2.5 mm² solid or stranded).